Load Amano Agp-1710 Manual

Posted on  by admin

. ® AGP-2000 Series Ticket Dispenser INSTALLATION / OPERATIONS MANUAL. We recommend that this document be read in its entirety before any attempt is made to oper- ate the equipment. PROPRIETARY NOTICE This document contains proprietary information and such information may not be reproduced in whole or in part without written permission from Amano Cincinnati, Inc., 140 Harrison Avenue, Roseland, New Jersey, 07068. TABLE OF CONTENTS Chapter 1: INTRODUCTION. 1-1 Chapter 2: SPECIFICATIONS.

  1. Amano Agp-1710 Parts
  2. Amano Agp 1710
Load

Manual For Amano Pix 10 View and Download Amano EX-3500 user manual online. EX-3500 Clock pdf manual Clock Amano PIX-10 Operation Manual. Electronic time recorder (40. Amano Pix-10 Manual View and Download Amano BX6000 operation manual online. BX6000 Series Electronic Clock Amano PIX-10 Operation Manual. Electronic time recorder (40. View and Download Amano AGP-2000 Series installation & operation manual online. Ticket Dispenser. AGP-2000 Series Dispenser pdf manual download.

AGP-2000 Installation and Operations / TABLE OF CONTENTS. Chapter 1: INTRODUCTION Figure 1-1, The AGP-2000 Ticket Dispenser The AGP-2000 Ticket Dispenser is designed for multiple uses at unattended entrances of a parking facility. In its traditional application, the AGP-2000 is installed at an entrance to automatically dispense a parking ticket with the date, time, ticket number, machine number and rate code printed and magnetically encoded on the ticket. 1 - 2 AGP-2000 Installation and Operations / INTRODUCTION. Chapter 2: SPECIFICATIONS Pedestal Size: 49 1/2” (126 cm) high x 17 3/4” (45 cm) wide x 21” (53 cm) deep Throat: 38 3/4” (98cm) high Weight: 135 lbs. (61 kg) Service: Polyethylene cover over top mechanism. Door panel on left side of pedestal.

Tickets: 2 1/8” (54 mm) wide x 3 3/8” (85 mm) long x.007” (.188 mm) thick. 5000 tickets per carton Refer to Amano’s Standard 3” Ticket Specifications (ATD-106900) Figure 2-2, Example of a Standard Printed Ticket Printer: Dual Automatic ticket feed.

Standard Features Loop Usage: Selectable via programming Arming Loop (A) Closing Loop (C) Memory: 999 transactions 1000 error messages 9999 pass cards Vault Box: 50 ticket capacity Alarm activated when 100% full Voice Unit: Delivers pre-programmed verbal instructions to patrons Messages are user programmable Built in intercom for direct communication (Aiphone™. Cabinet Design Upper Mechanism See Figure 2-3 below for the location of the following upper mechanism components: 1. Ticket Throat Ejects tickets 2. Printer Release Latch Access to clear ticket jams and change ribbon 3.

Printer Motor Drives the printer ribbon 4. Lower Mechanism See Figure 2-4 below for the location of the following lower mechanism components: 1. Cover High impact weatherproof cover 2. Rear Cover Latch Holds rear of cover in place 3. Thermal Package Thermostatically controlled heater 4. Interconnect PCB Communications interconnect with upper mechanism 5. 2 - 6 AGP-2000 Installation and Operations / SPECIFICATIONS.

AGP-2000 Programming Instruction Manual (ATD-107500) and this AGP-2000 Installation and Operations Manual. Any accessory kit will be shipped separately, along with installation information.

Notify Amano Cincinnati Inc. If any of these items are missing. Check the carton for shipping damage. If anything is damaged, notify the transportation company and file a claim.

Mounting the AGP-2000 Follow the instructions outlined below to mount the AGP-2000 Ticket Dispenser. Check the location of the installed conduits and anchor bolts against the bolt layout drawing below. Make sure the conduits extend more than 1” (2.5 cm) high but do not extend more than 2”. Electrical Connections Main Power The AGP-2000 power source must not drop below certain voltages, depending on the model of the Ticket Dispenser. A 120VAC model must not drop below 90VAC with a 7 ampere load. A 220/240VAC model must not drop below 180VAC with a 3.5 ampere load.

1710

The AGP-2000 is equipped with a main power Field Connect Box. Main Power Connections 12. Connect the GROUND wire from the field wiring to the GREEN wire inside the Field Connect Box. Replace the cover plate over the Field Connect Box. Connect the power source to field wiring only after all terminal block connections have been made. Communications Wiring This PCB provides RS485 communications connections from the host computer to the AGP-2000 if the unit is used in an on-line system (NEC Class 2 wiring only). The communications wire shielding must be tied to earth ground only at the device location furthest from the host computer.

Field Connections (24 VDC) Refer to Figure 3-3 for the location of the Field Connections Terminal Block (TB2) shown below. This terminal block supplies +24 VDC and 0 VDC for I/O Rack connections (NEC Class 2 wiring only). Figure 3-6, Field Connections Terminal Block TB2 with cover removed 3 - 6 AGP-2000 Installation and Operations / INSTALLATION. I/O Rack #1 Connections and Jumper Settings Refer to Figure 3-3 for the location of the I/O Racks. Figure 3-7 below illustrates I/O Rack #1 connections (NEC Class 2 wiring only) and Jumper Settings. Figure 3-7, I/O Rack #1 Connections and Jumper Settings AGP-2000 Installation and Operations / INSTALLATION 3 - 7.

I/O Rack #2 Connections and Jumper Settings Refer to Figure 3-3 for the location of the I/O Racks. Figure 3-8 below illustrates the optional I/O Rack #2 connections (NEC Class 2 wiring only) and jumpers. Order I/O Rack #2 as product #AGP-0502/A527. Driver bluetooth windows 7 dell vostro 3500 prices. Installation instructions are included in the kit. Figure 3-8, I/O Rack #2 Connections and Jumper Settings 3 - 8 AGP-2000 Installation and Operations / INSTALLATION. Typical Input/Output Modules The following figures illustrate typical Input and Output module schematics.

Figure 3-9, Typical 24VDC & 120VAC Input Module Schematic Figure 3-10, Typical 24VDC & 120VAC Output Module Schematics AGP-2000 Installation and Operations / INSTALLATION 3 - 9. AGP-2000 Connections to an AGP-1700 Gate Figure 3-11, AGP-2000 Connections to an AGP-1700 Gate 3 - 10 AGP-2000 Installation and Operations / INSTALLATION. AGP-2000 Connections to an AGP-1700 Gate and MAG-120 Reader Figure 3 - 12, AGP-2000 Connections to an AGP-1700 Gate and MAG-120 Reader AGP-2000 Installation and Operations / INSTALLATION 3 - 11.

Amano agp-1710 parts

AGP-2010 Schematic Figure 3-13, AGP-2010 Schematic 3 - 12 AGP-2000 Installation and Operations / INSTALLATION. Loading the Ticket Supply After the power and field wiring to the Ticket Dispenser have been connected, you are ready to load the tickets into the transport. Refer to Figure 2-4 for the location of installed ticket boxes.

Unlock and open the side door panel if you have not already done so. Intercom Wiring If you are using the AGP-2000 internal intercom, follow the wiring diagram below. Figure 3-15 AGP-2000 Intercom Wiring Diagram Complete the Installation After wiring connections and ticket loading are completed, proceed as follows: 1. Hang the vault box next to the vault reset switch underneath the RWPV™ (Read, Write, Print, Vault) mechanism. Chapter 4: SERVICE Door Open Switch The Door Open Switch is a safety switch inside the AGP-2000 cabinet.

It activates the Door Open alarm and sends a Door Closed status signal to the system host. Figure 4-1 below illustrates the Door Open switch and its two positions. Figure 4-1, The Door Open Switch Mode 1: When the door panel is in place, the switch is fully engaged for. Close and lock the cover and door panel when finished.

Amano Agp-1710 Parts

Note: Use only an RWPV ribbon (Amano part number CE-316250). This ribbon contains an ink tank which will assure long ribbon life (approximately 50,000 tickets). Generic ribbons may leak ink onto the platten, gum up the print head and not couple with the mechanism properly.

Amano Agp 1710

Ticket Jam If a ticket should become jammed in the ticket transport, the display will indicate the following: TICKET JAM 10/17/99 06:39A To clear the ticket jam, perform the following procedure: 1. Open the side door panel if you have not already done so. Ticket Restocking A Low Ticket situation occurs when the primary box of tickets is depleted and the secondary box of tickets is being used. There is no indication on the display when the Ticket Dispenser is low on tickets. An Out of Tickets situation occurs when the AGP- 2000 ticket supply is completely depleted. To recover from a restocking misfeed: If the tickets misfeed after restocking or while switching to a new box (dual ticket feed) the display will indicate the following: Closed F10/17/99 09:39A The character F or B will appear in the first position of the date/time display. If an F appears, the misfeed has occurred in the Front, or Dual Ticket Feed opening of the transport.

Issuing Lost Tickets If a customer loses a ticket, a replacement “lost ticket” is needed to validate the transaction at the exit. The AGP-2000 gives you the ability of issuing replacement lost tickets in advance. Follow the instructions below to issue lost tickets. Replace the vault bin. Figure 4-6, The Vault Bin Reset Switch Preventative Maintenance In order to keep your AGP-2000 running efficiently, Amano recommends that you perform the following Preventative Maintenance procedures: RWPV™: Use commercially available canned or compressed air to periodically blow out dust buildup from the read/write/print/vault mechanism.

Servicing the PCBs Refer to Figure 2-3 to locate the Interface PCB and Main Logic PCB, located on the right side of the mechanism. The PCB’s may require removal for replacement or service purposes. Note: Turn the Main Power Breakers off before removing either circuit board.

Use the appropriate static protection when handling the circuit boards. System Reset Program Reset The AGP-2000 program can be reset to the default values if needed. A System Reset is accomplished through the Test Mode. Press the POWER button on the remote control unit.

Press 2 to enter the Test Mode. 4 - 10 AGP-2000 Installation and Operations / SERVICE. AMANO CINCINNATI, INC. A Company of the AMANO Group/Yokohama 140 Harrison Avenue, Roseland, NJ 07098 Technical Support: (800) 526-2559 Atlanta Sales Office (770) 587-1082. (800) 554-1031 Chicago Sales Office (847) 718-1100.

(800) 323-8864 Cincinnati Sales Office (513) 697-9000. (800) 487-7564 Dallas Sales Office (972) 241-09146.